Lightning 7 expands Penumbra's offering of the Indigo Aspiration System with Intelligent Aspiration for mechanical thrombectomy and is designed for single session arterial thrombus removal. As part of the INDIGO Aspiration System, the INDIGO Aspiration Catheters and Separators are indicated for the removal of fresh, soft emboli and thrombi from vessels of the peripheral arterial and venous systems, and for the treatment of pulmonary embolism. Potential Adverse Events Warnings Do not use the INDIGO Aspiration System with a pump other than a Penumbra Aspiration Pump. Penumbra CAT8 KIT Indigo Aspiration Catheter 8 & Aspiration Tubing, XTorq Tip 115cm x 8F (NON-STERILE) Expired. Director of Cardiac Catheterization Lab, PERT & Structural Heart
Download scientific diagram | A, Penumbra Indigo System Continuous Aspiration Mechanical Thrombectomy Catheter (CAT8). Its engineers designed low-profile, high-power aspiration catheters called Cat 7 and Cat 12 that were launched in 2021. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower . Do not use in an oxygen rich environment. 1. Available in a selection of sizes, the CAT family can enable access to distal peripheral vessels of the upper and lower extremities, including below the knee. The Indigo System with Lightning Aspiration Tubing is a computer-aided aspiration system powered by Penumbra ENGINE. Penumbra System BENCHMARK Delivery Catheter - MP - 6Fr x .071" x 105cm - Non-Expired: 6Fr x .071" x 105cm $550.00. CAT RX mechanical aspiration system powered by Penumbra ENGINE in comparison to manual syringe-based aspiration. Penumbra System CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm - Non-Expired: 8Fr x 115cm 0: Contact Us: . 5 and 94. Results of EXTRACT-PE Trial presented at Vascular InterVentional Advances (VIVA) Annual Meeting Penumbra, Inc. (NYSE: PEN), a global healthcare company focused on innovative therapies, today announced that the EXTRACT-PE trial successfully met the primary endpoints, demonstrating the safety and efficacy of the Indigo Aspiration System for aspiration mechanical thrombectomy in patients with . The Penumbra ENGINE is indicated as a vacuum source for Penumbra Aspiration Systems. Equipment is not safe for MR use. The patient remained on cangrelor with no need for tirofiban. Available in a selection of sizes, the CAT family can provide access to distal peripheral vessels of the upper and lower extremities, including below the knee. Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System. Penumbra System ACE 68 KIT Reperfusion Catheter & Penumbra Hi-Flow Aspiration Tubing - 6Fr x .068" x 132cm: 6Fr x .068" x 132cm $600.00. Penumbra System CAT8 INDIGO System Aspiration Catheter 8 - XTORQ - 8Fr x 115cm - Non-Expired: 8Fr x 115cm 0: Contact Us: RBY2C0305 The Penumbra Aspiration Pump is indicated as a vacuum source for Penumbra Aspiration Systems. Additional Details. Distal OD. Cardiology; Dental; Emergency & EMT; Endoscopy; Exam & Diagnostic; . CAT7 and CAT12 are the next generation of the Indigo System Catheters. Do not use petroleum based compounds, acids, caustics, or chlorinated solvents to clean or lubricate any parts. Distal emboli causing PDA occlusion after manual aspiration. The Penumbra System is a fully-integrated system designed specifically for mechanical thrombectomy, first receiving 510(k) clearance by the FDA in December 2007. Excessive aspiration or failure to close the INDIGO Aspiration Tubing when aspiration is complete is not recommended. Mechanical clot engagement with proprietary Separator technology, Tip directionality for circumferential aspiration, The Indigo System is an integrated system for use only with other components of the Indigo System including the CAT family of catheters, Separators, Dynamic Aspiration Tubing, Lightning, Penumbra ENGINE, and Penumbra ENGINE Canister, Lightning Computer-Aided Aspiration comes packaged with CAT7 or CAT12, Live feedback during the procedure with integrated clot catcher, Penumbra ENGINE is capable of delivering and maintaining nearly pure vacuum (-29 inHg or 98.2 kPa) with the disposable Penumbra ENGINE Canister. 3. PENUMBRA ENGINE Indication for Use Resterilization and/or reuse may result in ineffective catheter coating lubrication, which may result in high friction and the inability to access the target vasculature location. Maintain a constant infusion of appropriate flush solution. The final angiographic outcome revealed complete revascularization and TIMI 3 flow (Figure 2). Warnings/Precautions Further evaluation of the returned device revealed kinks in the catheter shaft. Indigo Aspiration System (CAT RX and Separator 4)- Penumbra Engine Pump and Canister. Physicians in the USA have published details ofto their knowledgethe "first reported use" of the Indigo aspiration system (Penumbra) to treat cerebral venous sinus thrombosis (CVST) via endovascular thrombectomy.The treated patient underwent successful partial recanalisation of the superior sagittal sinus (SSS) and bilateral transverse sinuses (TS), and experienced . Indigo Aspiration Catheters (CAT) are the foundation of Penumbra's Indigo System.The Indigo System CAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. The INDIGO SEPARATOR is not intended for use as a guidewire. Copyright 2023 Penumbra, Inc. All rights reserved. minimalism: a documentary about the important things transcript; cat8 penumbra catheter; i 75 road construction cincinnati; tocaya west hollywood; best places to live in alabama near the. Angiography of the posterior tibial artery revealed embolization to the heel resulting in no flow to the foot (Figure 1). The patient received a 3.5- X 38-mm everolimus-eluting stent (Synergy drug-eluting stent [DES], Boston Scientific Corporation) with postdilation optimized by intravascular ultrasound (IVUS) and was then sent to the step-down unit. CHEETAH will focus on patients presenting with high-grade thrombus burden who receive frontline treatment with CAT RX. Cook Medical) with the Indigo System (Penumbra, Inc.) using a CAT8 catheter and SEP8 separator to maximise the debris removal. Each vessel was wired sequentially, delivering power aspiration via CAT RX to the site of each thrombus. With S. Jay Mathews, MD, MS, FACC; Chris Metzger, MD; Waqas R. Qureshi, MD, MS; Jawairia Sahar K. Mirza, MBBS; Gus Theodos, MD, FACC, FSCAI; Brian Kolski, MD; and Suhail Dohad, MD, FACC. Precautions UPC: Current Stock: This item is out of stock. Do not use petroleum base compounds, acids, caustics, or chlorinated solvents to clean or lubricate any parts. INDIGO Aspiration Catheters and Separators: (CAT3, CAT RX, CAT5, CAT6, CAT8, and CATD) and patented Separator technology, which maintains continuous aspiration and helps limit clogging of the catheters tip during the procedure. Prior to use, please consult device labeling and instructions for use. The pain became more intense and constant, so he presented to the ED. It will reduce service life of the Penumbra ENGINE. Within 72 hours, repeat echocardiography showed RV/LV ratio improvement from 1.43 to 0.98. Cedars Sinai Medical Center
PENUMBRA, INC. INDIGO SYSTEM ASPIRATION CATHETER 8 DXE: Back to Search Results: Model Number CAT8XTORQ115KIT-S: Device Problems Break (1069); Physical Resistance/Sticking (4012) Patient Problem No Clinical Signs, Symptoms or Conditions (4582) Event Date 05/19/2021: Potential Adverse Events Ballad CVA Heart & Vascular Institute
The Indigo SystemCAT3, CAT5, CAT6, CAT8 and CATD are engineered to be robust, durable, and trackable for use in the peripheral anatomy. The INDIGO SEPARATOR is not intended for use as a guidewire. Return all damaged devices and packaging to the manufacturer/distributor. Angiography was performed and confirmed complete thrombus removal and flow restoration through the SVG. The built-in microprocessor features a proprietary thrombus removal algorithm that automatically controls a valve in the tubing to provide continuous or intermittent aspiration. The Indigo Separator is advanced and retracted through the corresponding size Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip. These benefits may suggest a reduction to cost of care, improved patient outcomes, and changes to the procedural algorithm. The INDIGO Aspiration Tubing: gtag('config', 'UA-18982160-1'); Penumbra Inc .cls-1{fill:#a6a699;}.cls-2{fill:#b5121b;}.cls-3{isolation:isolate;fill:url(#linear-gradient);}. Worcester, Massachusetts
Unrestrained torquing or forced insertion of the catheter or SEPARATOR against resistance may result in damage to the device or vessel. 0, and 37. Mechanical thrombectomy was performed. Precautions Interventional Cardiology
Do not resterilize or reuse. The Penumbra CAT RX catheter was used in a total of 34 patients, with 71% STEMI, 23% NSTEMI, 3% UA, and 3% new onset heart failure. Maintain a constant infusion of appropriate flush solution. These pages are not intended for patients or for members of the general public. 22. Most recently, Penumbra launched Lightning Intelligent Aspiration which enables physicians to focus on optimizing thrombus removal using the system's unique clot detection mechanism. After one pass with CAT RX, the high thrombus burden was removed, resulting in TIMI 3 flow. Figure 1. This warranted the need for further innovation in the field of acute coronary syndrome.2 The goal of the Indigo System CAT RX mechanical aspiration system powered by the Penumbra ENGINE is to provide sustained aspiration for the duration of the procedure with enhanced deliverability to navigate tortuous anatomy and track to the distal coronary vasculature. Final angiography was performed, showing complete resolution of the underlying lesion (Figure 2). 0 cm from the hub. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 12 inches (30 cm) to any part of LIGHTNING Aspiration Tubing. Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Penumbra ENGINE. The Indigo Separator is advanced and retracted through the corresponding size Indigo catheter at the proximal margin of the primary occlusion to facilitate clearing of the thrombus from the catheter tip. The Indigo System met its efficacy and safety endpoints by reducing right-to-left ventricle (RV/LV) ratio at 48 hours by 27.3% (mean ratio reduction, 0.43; 95% confidence interval, 0.380.47; P < .0001) and had a low major adverse event of 1.7% (2/119). If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally. If repositioning of the Indigo CAT RX Aspiration Catheter is necessary during the revascularization procedure, such repositioning should be performed over an appropriate guidewire using standard guidewire techniques. Catheters; CAT8 KIT Indigo System Aspiration Catheter 8 and Aspiration Tubing - XTORQ - 8Fr x 115cm . The large aspiration lumen and highly trackable, low-profile design coupled with the power of the Penumbra ENGINE resulted in the successful removal of the emboli in one pass. Her heart rate was 110 beats per minute, elevated troponin levels at 4.5 ng/mL, and elevated brain natriuretic peptide at 1,164 pg/mL.